WIRES & CABLES

3 Core Double Sheath Round Submersible Cables

Applicable standards

IEC 60502-1, KS IEC 60227, IS 694, KS EAS 117, IEC 60227, IEC 60811-1-1, IEC 60719, KS IEC 60038

Construction

Conductor: Class 5 and 6 flexible copper conductors.
Insulation: PVC compound
Inner and outer sheath cover: PVC compound, Blue or Black
Core identification colours: Green/yellow, blue, brown

Specifications

Permissible operating temperatures; -20 °C to 70°C maximum
Nominal voltage: 600/1000V (Um 1200V)
Test voltage: 3.5kV/5Mins
Minimum bending radius: 6 x Diameter

Special Features

They are designed for permanent immersion, are non toxic, water proof and resistant to oil, grease

Applications

Drinking water supply, Borehole water pumps, Drink manufacturing industry, Fish ponds, Swimming pools, offshore drilling rigs, Sewer treatment plants, power connections on wetlands and general electrical installations.

Permissible operating temperatures; -20 °C to 70°C maximum
Nominal voltage: 600/1000V (Um 1200V)
Test voltage: 3.5kV/5Mins
Minimum bending radius: 6 x Diameter

SIZES, DIMENSIONS AND RATING

Conductor Insulation cover Total thickness of double sheath Maximum conductor resistance at
20°C, Ω / km
Current rating at 40°C Amps
Nominal size, mm2 No. and dia. of strands Nominal thickness, mm Nominal core diameter, mm Oversheath thickness, mm Approximate overall dia. mm
1.5 22/0.3 0.6 3.0 1.7 10.0 13.30  
2.5 36/0.3 0.7 3.6 1.7 11.0 7.980  
4.0 56/0.3 0.8 4.3 1.8 13.0 4.950  
6.0 84/0.3 0.8 5.1 1.9 14.6 3.300  
10.0 140/0.3 1.0 6.5 2.0 18.0 1.910  
16.0 224/0.3 1.0 8.0 2.0 21.2 1.210  
25.0 350/0.3 1.2 10.1 2.4 26.5 0.780  
35.0 490/0.3 1.2 11.3 2.6 29.5 0.554  
50.0 703/0.3 1.4 13.3 3.1 34.8 0.386  
70.0 988/0.3 1.4 15.3 3.2 39.3 0.272  
95.0 1349/0.3 1.6 18.0 3.5 47.7 0.206  
 

All Domestic Cables we produce are Fire Retardant.